Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Automatic Climate Controls (RPO C68)

TEMPERATURE VALVE LINK ADJUSTMENT
1. Pull valve link from retainer on programmer output crank (if not previously disassembled).
2. Start vehicle; set temperature to 32°C (90°F).
3. Allow 45 seconds minimum for programmer motor to move output crank to its full hot position. Then move temperature valve to full hot position; snap valve link into retainer on output crank.