Circuit Operation
The Powertrain Control Module (PCM) controls both Cooling Fans by controlling three relays through two outputs. There are two modes of cooling fan operation low speed and high speed. In the low speed mode the cooling fans are powered in series, Cooling Fan 1 Relay is energized by the PCM and both cooling fans run at low speed. In the high speed mode the cooling fans are powered in parallel which allows the fans to run at high speed. Cooling fans operate only when the ignition is in RUN.Low Speed Conditions
The PCM will turn on the cooling fans at low speed when the engine coolant temperature exceeds 106° C (223° F). The cooling fans will be turned off when the engine coolant temperature falls below 102° C (215° F). The PCM monitors engine coolant temperature using the engine coolant temperature sensor input at terminal 1B5 through CKT 410.
The PCM will also activate low speed operation if the transaxle temperature exceeds 115°C (239° F). The cooling fans will be turned off when the transaxle temperature falls below 110°C (230° F). The PCM monitors transaxle temperature using the transaxle temperature sensor input at terminal 1B14 through CKT 585.
The Heater and A/C Programmer will request the PCM to turn on the cooling fans at low speed through the UART data line when the A/C high side refrigerant temperature exceeds 50°C (122° F). The Programmer will request that the cooling fans be turned off once the A/C high side refrigerant temperature falls below 47°C (117° F).
The PCM will turn on the cooling fans at low speed if a low coolant level is detected and the engine coolant temperature exceeds 80° C (176° F). The cooling fans will be turned off when the engine coolant temperature drops below 76° C (168° F). The PCM monitors coolant level using the coolant level switch input at terminal 1B16 through CKT 1478.
Low Speed Operation
Low speed cooling fan operation will occur when the PCM grounds Cooling Fan 1 Relay's coil through CKT 335 at terminal 3F8. With only Cooling Fan 1 Relay energized, Voltage is applied to both the LH and RH Cooling Fan Motors. The voltage path to the motors is through the Cooling Fan 1 Relay's contacts, CKTS 532, 504 and 409, and the Cooling Fan 2 Relay's contacts. The two motors are connected to each other through a series circuit. This causes the voltage being applied by MAXI Fuse 3 to be divided between the two motors. The division of the voltage causes the motors to operate a a lower speed. In the series mode the fans are grounded through CKT 250 and ground G107.
High Speed Conditions
The PCM will turn on the cooling fans at high speed when the engine coolant temperature exceeds 110°C (230° F) or the Engine Coolant Temperature Sensor circuit has failed. The PCM will switch the cooling fans to low speed operation once the engine coolant temperature falls below 105°C (221° F).
The PCM will also activate high speed operation if the transaxle temperature exceeds 120°C (250° F). The PCM will switch to low speed operation once the transaxle temperature falls below 115° C (239° F).
The PCM will turn on the cooling fans at high speed if a low coolant level is detected and engine coolant temperature exceeds 85°C (185° F). The PCM will switch to low speed operation once the engine coolant temperature drops below 80° C (176° F).
The Heater and A/C Programmer will request the PCM to turn on the cooling fans at high speed through the UART data line if the A/C high side refrigerant temperature exceeds 64°C (147° F). The Heater and A/C Programmer will request that the cooling fans be switched to low speed operation when the A/C high side refrigerant temperature falls below 51°C (124° F).
High Speed Operation
The cooling fans run at high speed when Cooling Fan 1, 2, and 3 Relays are grounded by the PCM terminals 3F8 and 3F7 through circuits 335 and 473. With cooling Fan 1 Relay energized, battery voltage is applied to the LH Cooling Fan Motor through the relay contacts. The LH Cooling Fan Motor runs at high speed because now the fan motor is grounded directly through the contacts of the Cooling Fan 2 Relay CKT 350 and ground G109.
Since Cooling Fan 3 Relay is also energized during high speed operation, battery voltage is applied directly to the RH Cooling Fan Motor through the closed contacts of the relay. The fan will run at high speed since it is no longer in series with the LH Cooling Fan Motor.