Catalytic Converter: Service and Repair
Three Way + Oxidation Catalytic Converter Attachments:
CATALYTIC CONVERTER REMOVAL AND INSTALLATION PROCEDURE
Remove or Disconnect
1. Raise and suitably support vehicle.
2. Converter bolts/screws (36) (Refer to accompanying image for numbered references) at intermediate pipe assembly (30).
3. Intermediate pipe assembly (30) from converter (29).
4. Converter clamp assembly (32) at crossover pipe assembly (19).
5. Hanger bolts/screws (34).
6. Vibrate dampener assembly (37).
7. Converter (29). Rotate converter (29) while sliding off crossover pipe assembly (19).
Install or Connect
1. Converter (29) to crossover pipe assembly (19).
2. Vibrate dampener assembly (37).
3. Hanger bolts/screws (34). Tighten hanger bolts/screws (34) to 41 Nm (30 ft lb).
4. Converter clamp assembly (32) at crossover pipe assembly (19). Tighten nuts on converter clamp assembly (32) to 35 Nm (26 ft lb).
5. Intermediate pipe assembly (30) to converter (29).
6. Converter bolts/screws (36) at intermediate pipe assembly (30). Tighten converter bolts/screws (36) to 20 Nm (15 ft lb).
7. Lower vehicle.