IPC PRNDD21 Indicators Flashing
PRNDD21 Circuit:
TEST CONDITION:
Same as test conditions for code B127.
FAILURE CONDITION:
Same as failure conditions for code B127 except there is a shorter (2 second) time delay.
ACTION TAKEN:
All PRNDL boxes will flash on and off.