Bank 2
REMOVAL PROCEDURECAUTION: Allow the engine to Cool before servicing the secondary Air Injection AIR system in order to reduce the chance of severe burns.
1. Turn OFF the ignition.
2. Disconnect the clamp and AIR hose from the AIR Check valve.
3. Disconnect the vacuum line from the check valve.
4. Remove the AIR pipe nut from the air pipe bracket.
5. Disconnect the Air pipe assembly from the adaptors on the right exhaust manifold.
6. Remove the right AIR pipe assembly from the manifold.
7. Remove the two bolts from the bottom of the check valve.
8. Separate the check valve from the AIR pipe.
INSTALLATION PROCEDURE
1. Reinstall the two bolts through the pipe into the check valve.
2. Place the check valve/pipe assembly onto the bracket stud and manifold adaptors.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Tighten
Tighten the pipe to the manifold adaptors to 10 N.m (88 lb in).
4. Reinstall the nut on bracket stud.
Tighten
Tighten the locknut to 10 N.m (88 lb in).
5. Connect the vacuum line to the check valve.
6. Connect the clamp and AIR hose to the AIR Check valve.