Refrigerant Pressure Sensor / Switch: Description and Operation
An electronic A/C pressure transducer is mounted on the discharge line (high side) of the A/C compressor suction/discharge hose assembly. Its output to the PCM is variable and is dependent upon pressure inside the line. A higher pressure results in a higher voltage output. A/C pressure is constantly monitored to:
^ Disengage the A/C clutch if the pressures are high
-2700 kPa (430 psi).
^ Disengage the A/C clutch if pressures are too low
-below 303 kPa (44 psi).
^ Control cooling fan operation of low and high speed.