A/C Pressure Sensor/Switch - Cooling Fan: Service and Repair
Remove or Disconnect
1. Electrical connection from switch.
2. Switch and O-ring seal.
Install or Connect
1. Switch using a new O-ring seal.
^ Lube O-ring with 525 refrigerant oil.
Tighten
^ Switch to 5 N.m (44 lb. in.).
2. Electrical connection to switch.