Generator Replacement
Generator 3100:
IMPORTANT: The CS130D generator is serviced as a complete unit only.
REMOVE OR DISCONNECT
CAUTION: Refer to Service Precautions.
1. Battery ground (negative) cable.
2. Drive belt from generator.
3. Bolts/screws from generator.
4. Stud from generator.
5. Electrical connector from generator.
6. Loosen generator front and rear braces from intake manifold.
7. Nut and battery positive lead from generator output "BAT" terminal.
8. Generator.
INSTALL OR CONNECT
NOTE: Refer to Service Precautions.
1. Position generator to bracket.
2. Battery positive lead and nut to generator output "BAT" terminal.
Tighten
^ Nut to 20 N.m (15 lb. ft.).
3. Hand start generator front and rear brace nuts to intake manifold.
4. Electrical connector to generator. Connector will snap in place when correctly installed.
5. Hand start generator rear brace bolt/screw to generator.
6. Generator to generator mounting bracket bolts/screws.
Tighten
^ Bolts/screws to 50 N.m (37 lb. ft.).
7. Generator front and rear brace to intake manifold nuts.
Tighten
^ Nuts to 25 N.m (18 lb. ft.).
8. Generator rear brace bolt/screw to generator.
Tighten
^ Bolt/screw to 25 N.m (18 lb. ft.).
9. Drive belt to generator.
10. Battery ground (negative) cable.