Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Circuit Operation - Volts Indicator

Battery voltage is applied to the instrument Cluster through I/P Fuse #11 whenever the Ignition Switch is in "RUN," "BULB TEST" or "START." A ground is provided at the Generator "L" terminal when the Regulator senses a high or low voltage condition or when the Rotor stops turning.