Dieseling/Run-On

TEST DESCRIPTION
Engine continues to run very roughly after key is turned off.

INSPECTION
1. Check injectors for leaking. See Chart A-7.
Chart A4-7 Fuel System Diagnosis

2. If engine runs smoothly, check ignition switch and adjustment.