32 41 285 Replacing Level Switch For Dynamic Drive Fluid Reservoir

32 41 285 Replacing level switch for Dynamic Drive fluid reservoir





Necessary preliminary work:
^ Remove intake port for air filter housing





Release screws (1) and (2).

Remove washers.

Tightening torque 32 41 1AZ/ 2AZ

Remove fluid reservoir by pulling upwards.





Note:
Raise and/or turn fluid reservoir in order to gain better access to plug connection.

Disconnect plug connection (1).

Turn level switch (2) through approx. 45° and remove towards bottom.