12 14 513 Replacing Pulse Generator on Right Exhaust Camshaft



12 14 513 Replacing Pulse Generator On Right Exhaust Camshaft (N74)

(cylinder bank 1 to 6)







Necessary preliminary tasks:
- Read out fault memory of DME control unit; if necessary, work through test schedules
- Turn off ignition
- Remove right intake filter housing
- Remove right suspension cross-brace
- Remove sound insulation from bulkhead on right
- Remove right throttle body







Unlock plug (1) and remove.
Release screw (2).
Tightening torque 13 62 2AZ.
Remove pulse generator (3).

Installation:
Replace sealing ring and coat with antiseize agent.







NOTE: Delete fault memory.