12 14 526 Replacing Pulse Generator on Right Inlet Camshaft



12 14 526 Replacing Pulse Generator On Right Inlet Camshaft (N63)

(cylinder bank 1 to 4)







Necessary preliminary tasks:
- Read out fault memory of DME control unit; if necessary, work through test schedules
- Switch off ignition
- Remove right intake filter housing







Unlock plug (1) and remove.
Release screw (2).
Tightening torque 13 62 3AZ.
Remove pulse generator (3).

Installation:
Replace sealing ring and coat with antiseize agent.







NOTE: Now clear the fault memory.