Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Power Supply And DDE Main Relay



Power Supply And DDE Main Relay

The power supply for the DDE control unit is provided via the 8-pin control unit connector.

Function
The power supply to the DDE control unit follows the following sequence when the ignition is switched on:
- With ignition ON, voltage is applied to the DDE control unit via terminal 15WUP and terminal 15_3.
- The DDE main relay is switched via the signal 30B.
- The DDE main relay switches terminal 30 via U_HR to the DDE control unit.

Troubleshooting
The following faults are monitored in the voltage supply system:
- Fault 254E00/254D00: Voltage of power supply to DDE control unit too high/low
- Fault code 274900: DDE main relay switches off too early, possibly due to undervoltage.