Front
Caution: Read and comply with General Data, refer to Brakes and Traction Control, Description and Operation.
Open cover (1).
Remove plug connection (2) from fixture and disconnect.
Installation: Ensure proper locking of plug connector and proper seating of rubber grommets.
Release hexagon-socket-head cap screws (1).
Pull cable out of fixtures.
Withdraw ABS pulse generator from bore.
Installation:
Clean hole for pulse generator and grease with lubricating grease Staburags NBU 12/K.
Tightening torque: 8 Nm