Replacing Pulse Generator




Replacing Pulse Generator (A5S 440Z)
(Driving or turbine speed)
(Oil sump removed)






Pulse generator driving speed:
Release screw, remove retainer (1) and pulse generator (2) from transmission housing.

Installation:
Tightening torque, refer to Specifications.






Disconnect cable plug (1) from pulse generator (2).






Pulse generator turbine speed:
Release screw, remove retainer (1) and pulse generator (2) from transmission housing.

Installation:
Secure cable to retainer (3). Tightening torque, refer to Specifications.






Disconnect cable plug (1) from pulse generator (2).