Defect Code 97
Defect Code 97:
*D* Detect Code Memory: 97 Excess current at general module outputs:
Explanation: The output current of following GM outputs are monitored internally in the general module (GM). The defect code is set when an impermissibly output current is measured.
Monitored GM outputs:
- Interior light: GM connector yellow Pin 12 (k29)
- ES relay activation: GM connector yellow Pin 24 (for K30 relay) and Pin 25 (for K15 relay)
- activation lines from GM to PM: All PM functions, power windows, ZV, wiper etc. controlled via these lines. All PM functions are deactivated in the case failure of these lines.
- (GM connector yellow to RM connector 26-pole)
- GM Pin 4 to PM Pin 13
- GM pin 3 to RM Pin 11
- GM Pin 2 to PM Pin 26
Possible causes:
- Wires
- Defective components
Troubleshooting: As displayed on screen