Preparations For Checking Seat Bolster Adjuster For Leaks







Preparations for Checking Seat Bolster Adjuster for Leaks

When an appropriate entry is made in the event memory, you are prompted in "Guided Fault Finding" to perform a leak check. Refer to Vehicle diagnostic tester.

Then the preparations for this leak test are described that must be carried out directly in the front seat.

Connection diagram with assignment of the pneumatic lines to the air cushions. Refer to => [ Pneumatic Components on Multi-contour Seat, Connection Diagram ] Pneumatic Components on Multi-Contour Seat, Connection Diagram.

Procedure






The backrest cover must be removed. Refer to => [ Backrest Cover ] Backrest Cover.

- Move the front seat all the way forward/up.

- Carefully release latch - arrow -, disconnect pneumatic lines - 1 - and - 2 -.

- For checking in the "Guided Fault Finding", connect the air cushion and valve block connections in a diagonal sequence as follows:






For the connection of the pneumatic lines, prepare auxiliary hose from hose (VAS 6618/5) and connectors (VAS 6618/6) and (VAS 6618/7).

In one of the test steps in the "Guided Fault Finding", you are prompted to disconnect the pneumatic lines at the multi-contour seat control module (J872) / (J873).






- Before disconnecting, mark the assignment of the pneumatic lines to each other using a waterproof permanent marker.

- Disconnect pneumatic lines to the seat bolster inflation adjuster air cushions at the following points. Refer to => [ Disconnecting and Connecting Pneumatic Lines ] Disconnecting and Connecting Pneumatic Lines:

a 40 mm
b 40 mm

- For checking in the "Guided Fault Finding", connect the air cushion and valve block connections in a diagonal sequence as follows:






- For the connection, attach connecting sleeve (VAS 6618/3) to the pneumatic lines.






For the connection, insert pneumatic lines in the connecting sleeves (VAS 6618/3) of both sides - A arrows -.

Because of the danger of leaks, do not place the connecting sleeves in a bend in the hose.

To release, push release rings - B arrows - and simultaneously remove pneumatic lines - C arrows -.

- Connect pneumatic lines following the leak check. Refer to => [ Disconnecting and Connecting Pneumatic Lines ] Disconnecting and Connecting Pneumatic Lines.