Oxygen Sensors Assembly Overview
Oxygen Sensors Assembly Overview
Heated Oxygen Sensor (G39) before Catalytic Converter and Oxygen Sensor after Three Way Catalytic Converter (G130) Cylinder Bank 1 (right):
1. Oxygen sensor after three way catalytic converter (G130)
2. Heated Oxygen Sensor (G39) (before catalytic converter)
Removing and installing, refer to => [ Oxygen Sensors ] Oxygen Sensors.
• Tightening specifications: 55 Nm
Heated Oxygen Sensor 2 (G108) before Catalytic Converter and Oxygen Sensor 2 after Catalytic Converter (G131) Cylinder Bank 2 (left)
1. Heated oxygen sensor 2 (G108) (in front of catalytic converter)
2. Oxygen sensor 2 after catalytic converter (G131)
Removing and installing, refer to => [ Oxygen Sensors ] Oxygen Sensors.
• Tightening specifications: 55 Nm
Right Cylinder Bank 1 Oxygen Sensor Connectors
1. For Oxygen sensor after three way catalytic converter (G130)
2. For Heated oxygen sensor (G39)
Left Cylinder Bank 2 Oxygen Sensor Connectors
1. For oxygen sensor 2 after catalytic converter (G131)
2. For heated oxygen sensor 2 (G108)
• New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.
• For a used oxygen sensor, only coat threads with hot bolt paste. This paste must not come into contact with oxygen sensor slots.
• Wiring connection of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.