Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Oxygen Sensors Assembly Overview






Oxygen Sensors Assembly Overview

Heated Oxygen Sensor (G39) before Catalytic Converter and Oxygen Sensor after Three Way Catalytic Converter (G130) Cylinder Bank 1 (right):





1. Oxygen sensor after three way catalytic converter (G130)

2. Heated Oxygen Sensor (G39) (before catalytic converter)

Removing and installing, refer to => [ Oxygen Sensors ] Oxygen Sensors.

Tightening specifications: 55 Nm

Heated Oxygen Sensor 2 (G108) before Catalytic Converter and Oxygen Sensor 2 after Catalytic Converter (G131) Cylinder Bank 2 (left)





1. Heated oxygen sensor 2 (G108) (in front of catalytic converter)

2. Oxygen sensor 2 after catalytic converter (G131)

Removing and installing, refer to => [ Oxygen Sensors ] Oxygen Sensors.

Tightening specifications: 55 Nm

Right Cylinder Bank 1 Oxygen Sensor Connectors





1. For Oxygen sensor after three way catalytic converter (G130)

2. For Heated oxygen sensor (G39)

Left Cylinder Bank 2 Oxygen Sensor Connectors





1. For oxygen sensor 2 after catalytic converter (G131)

2. For heated oxygen sensor 2 (G108)

New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.

For a used oxygen sensor, only coat threads with hot bolt paste. This paste must not come into contact with oxygen sensor slots.

Wiring connection of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.