Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Oxygen Sensors, G39, G131, G285 and G288






Oxygen Sensors, G39, G131, G285 and G288

Special tools, testers and auxiliary items required

Ring spanner 7-piece set for oxygen sensor (3337)

Removing

All cable ties opened or cut during engine removal must be reinstalled at the same locations during installation.

- Loosen quick-release fasteners - 2 - and remove rear noise insulation.





- Remove bracket from subframe - arrow -.





- Remove affected oxygen sensor electrical connector from bracket on transmission.

1 Brown connector for Oxygen Sensor (O2S) 4 Behind Three Way Catalytic Converter (TWC) (G288)
2 Brown connector for Heated Oxygen Sensor (HO2S) 3 (G285) (in front of catalytic converter)
3 Black connector fro Heated Oxygen Sensor (HO2S) (G39) (in front of catalytic converter)
4 Black connector for Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131)

- Disconnect affected electrical connector and free up electrical wiring.

- Remove affected oxygen sensor using tool from Ring spanner 7-piece set for oxygen sensor (3337).





1. Heated Oxygen Sensor (HO2S) 3 (G285) (in front of catalytic converter)

2. Oxygen Sensor (O2S) 4 Behind Three Way Catalytic Converter (TWC) (G288)

3. Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131)

4. Heated Oxygen Sensor (HO2S) (G39)(before catalytic converter)

Installing

Installation is in reverse order of removal, note the following:

New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.

For a used oxygen sensor, only coat threads with hot bolt paste. This paste must not come into contact with sensor slots.

Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.

Tightening specifications. Refer to => [ Oxygen Sensors Assembly Overview ] Oxygen Sensors Assembly Overview