With Manual Transmission






Left Front Exhaust Pipe with Catalytic Converter

Removing

All cable ties which are opened or cut open when removing, must be replaced in the same position when installing.

- Remove rear engine cover - arrows -.





- Remove coolant expansion tank - arrow -.





- Disconnect electrical connection from Engine Coolant Level (ECL) Warning Switch (F66) at bottom of coolant reservoir and set aside coolant reservoir with coolant hoses - 1 - and - 2 - connected.

- Disconnect electrical harness connector - 1 - for Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) and free up wiring.





Ignore - 2 -.

- Remove nut - 2 - which is accessible from top for front exhaust pipe/exhaust manifold.





To improve clarity, the removed engine is shown from the rear.

- Remove left front wheel.

- Loosen quick-release fasteners - 1 through 3 - and remove front and rear noise insulation.





- Remove heat shield - arrows - for left drive axle.





- Remove nuts - 1 - and - 3 - which are accessible from bottom for front exhaust pipe/exhaust manifold.





To improve clarity, the removed engine is shown.

- Remove bolt - 1 - and nut - 2 -.





- Remove bracket for front exhaust pipe.

- Disconnect exhaust system at clamping sleeve - left arrow -.





- Remove front exhaust pipe with catalytic converter.

Installing

Installation is in reverse order of removal, noting the following:

Replace gaskets and self-locking nuts.

During installation, all cable ties must be re-installed at the same location.

Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.

- Align exhaust system. Refer to => [ Exhaust System, Installing ] Exhaust System, Installing.

Individual components of exhaust system mounting => [ Individual left mounting components - vehicles
with manual transmission ] Exhaust System Component Overview

Tightening specifications