Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Evaporative Emission (EVAP) Canister Purge Regulator Valve N80, Checking



Evaporative Emission (EVAP) Canister Purge Regulator Valve N80, Checking

Special tools, testers and auxiliary items required
- Multimeter V.A.G 1526 or equivalent.
- Test Box 105 Pin VAG1598/42.
- Adapter Lead Vag1598/39 VAG1598/39.
- Adapter cable V.A.G 1598/39-1.

Test requirements
- The fuse for the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80 OK.
- The ignition switched off.

NOTE Voltage for the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80 is supplied via the Engine Component Power Supply Relay J757.

Procedure
- Disconnect the electrical harness connector - 3 - from the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80.

Checking internal resistance
- Using the Multimeter V.A.G. 1526 A or equivalent, check the resistance between the terminals of the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80 .
Specified value: 22,0 to 30,0 Ohms.

If the specified value is not obtained:
- Replace the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80.

Checking voltage supply

If the specification is obtained:







- Using the Multimeter V.A.G. 1526 A or equivalent, check the electrical harness connector terminal 1 to 2 for voltage.
- Operate the starter briefly.
Specified value: approx. battery voltage

If there is no voltage:
- Using the Multimeter V.A.G. 1526 A or equivalent, check the electrical harness connector terminal for voltage.

Harness connector Terminal Measure to
1 Engine Ground (GND)

- Operate the starter briefly.
Specified value: aprox. battery voltage

If there is no voltage again:
- Check the wiring connection from the electrical harness connector terminal 1 to the Leak Detection Pump (LDP) -V144- terminal 3 for an open circuit according to wiring diagram.
Specified value: Wire resistance max 1.5 Ohms.
- If necessary, repair the wiring connection.

If the voltage supply is OK:

Check Ground (GND) activation







- Using the Multimeter V.A.G. 1526 A or equivalent, check the electrical harness connector for voltage.

Harness connector Terminal Measure to
2 Battery positive (+)

- Operate the starter briefly.
Specified value: aprox. battery voltage.

- Switch the ignition off.

If the specified value is not obtained:
- Connect the test box 1598/42 to the wiring harness of the Engine Control Module (ECM) J623. The ECM is not connected.







- Using the Multimeter V.A.G. 1526 A or equivalent, the following wire connection for open circuit.

Harness connector Terminal Test box Socket
2 49

Specified value: Wire resistance max 1.5 Ohms.
Specification: 0 Ohms.

If the specification is not obtained:
- Check the wiring for a short circuit to Battery positive (+) or an open circuit.
- If necessary, repair the wiring connection.

If the specification is obtained:
- Replace the Engine Control Module (ECM) J623

Final procedures
After repair work, the following work steps must be performed in the mentioned sequence:
1. Check the DTC memory.
2. If necessary, erase the DTC memory.
3. If the DTC memory was erased, generate readiness code.

- End diagnosis and switch the ignition off.