Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Basic Setting (Function 04)



Basic setting

With engine stopped and ignition switched on, the following operation can be performed with the "Function 04" basic setting:

- Adaptation of the throttle valve control module to the engine control module display group 60:

With the "engine running", the following operations can be performed in the basic setting mode "Function 04":

- Adaptation of the oxygen sensor control.
Oxygen Sensor Before Catalyst, Checking
- Troubleshooting by selective activation and deactivation of the oxygen sensor control.
Oxygen Sensor Before Catalyst, Checking

Test conditions for operations with engine running

- No DTC stored in DTC memory
- Coolant temperature at least 85 degrees C.
- Electrical consumers switched off (radiator fan must not run during the check)
- Air conditioner switched off
- Gear selector lever in P or N position
- Wheels in straight-ahead position
- Connect Vehicle Diagnostic, Testing and Information System VAS 5051 or V.A.G 1551 Scan Tool and select engine electronics control module 1 with "Address word" 01. For this purpose, engine must be running at idle speed.
Connecting VAS 5051 Scan Tool

- Checking and erasing Diagnostic Trouble Code (DTM) memory. No DTCs must be stored (if necessary, correct malfunction, erase DTC memory, switch off and re-start engine, perform test drive and check DTC memory again.
- Leave engine idling.

Indicated on display


Rapid data transfer HELP
Select function XX



- Press keys 0 and 4 for function "Basic Setting" and confirm entry by pressing Q key.

Indicated on display


Basic setting
Enter display group number XXX



- Select required display group number from display group overview in "Measured Value Block" section.

NOTE: Display group number 000 is used here as an example to demonstrate the procedure.

- Press key 0 three times.

(000 is used to select the function "display group 000").

NOTE: After the display group number is selected, the EGR valve is closed and the air conditioner compressor is switched off.

Indicated on display


Basic setting Q
Enter display group number 000



- Confirm entry with Q key.

Indicated on display


System in basic setting 0 ->
1 2 3 4 5 6 7 8 9 10



Display Group 000:






- Allow engine to idle for a few minutes; coolant temperature at least 85 degrees C (display zone 1: at least 180).

NOTE:
- Each time the PRINT key is pressed, the current display readout is printed out.
- Press the C key before selecting further display groups.

- If specifications are achieved in all display zones, press -key.

Indicated on display


Rapid data transfer HELP
Select function XX



- Press keys 0 and 6 for "End output" function and press Q key to confirm entry.

Indicated on display


Rapid data transfer HELP
Select function XX