Charge Pressure Control System, Overview
Charge pressure control system, overview
1 - Vent pipe
^ For Wastegate Bypass Regulator Valve -N75-
^ To left connecting pipe
2 - Wastegate Bypass Regulator Valve -N75-
3 - Pressure unit for charge pressure control
^ For turbocharger, cylinder bank 1 (right)
4 - Control pipe
^ Between Wastegate Bypass Regulator Valve -N75- and turbochargers
5 - Pressure pipe
^ Supply pipe for control pressure
^ From turbocharger, cylinder bank 2 (left)
^ To Wastegate Bypass Regulator Valve -N75-
6 - Pressure unit for charge pressure control
^ For turbocharger, cylinder bank 2 (left)