Adaptation (Function 10)



Adaptation (Function 10), Ultrasonic Interior Monitoring

Adaptation can be used to adjust and store the sensitivity level of the ultra-sound sensors.

Carrying out "Adaptation" function 10

Indicated on display

Rapid data transfer HELP
Select function XX


- Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display

Rapid data transfer Q
10 - Adaptation


- Press -Q- button to confirm input.

Indicated on display

Adaptation
Insert channel number XX


- Press buttons -0- and -1- to insert channel number 10.

Indicated on display

Adaptation Q
Insert channel number 10


- Press -Q- button to confirm input.

Indicated on display

channel 1 Adaptation 100 ->
Sensitivity in % (-1 3-)


The display will show the sensitivity level of the sensors, e.g. 100%.

NOTE: The maximum sensitivity level for the ultra-sound sensors is 100% (factory setting). This can be reduced to 50%.

- Press -> button.

Indicated on display

Channel 1 Adaptation 100
Input adaptation value XXXXX


- Input sensitivity level (e.g. 75% = 00075)

Indicated on display

Channel 1 Adaptation 100 Q
Input adaptation value 00075


- Press -Q- button to confirm input.

Indicated on display

Channel 1 Adaptation 75 Q
Sensitivity in % (-1 3-)


- Press -Q- button to confirm input.

Indicated on display

Channel 1 Adaptation 75 Q
Store changed value?


- Press -Q- button to confirm input.

Indicated on display

Channel 1 Adaptation 75 ->
Changed value is stored


- Press -> button to end adaptation procedure for sensitivity level.

Indicated on display

Rapid data transfer HELP
Insert address word XX