Adapting Fuel Consumption Display (Direct Input Method)



Adapting Fuel Consumption Display (Direct Input Method)

Indicated on display


Rapid data transfer HELP
Select function XX



- Press buttons -1- and -0- to select "Adaptation" function 10 and press -Q- button to confirm input.

Indicated on display


Adaptation Q
Insert channel number XX



- Press buttons -0- and -3- to insert channel 03.
- Press -Q- button to confirm input


NOTES:
- The value entered must be between 85% and 115%.
- Input is in steps of 5%.


Indicated on display


Channel 3 Adaptation 100 ->
<-1 3->



- Press -> button.


NOTE: Correction of the fuel consumption display is only carried out with the direct input method.

Indicated on display


Channel 3 Adaptation 100
Input adaptation value XXXXX



- Input desired correction value using keypad on VAG1551, fill in leading digits with zeroes "0".

Example:
Desired input value: 90%
Keyboard entry: 00090

Indicated on display


Channel 3 Adaptation 100 Q
Input adaptation value 00090



- Press -Q- button to confirm input

Indicated on display


Channel 3 Adaptation 90 Q
Store changed value?



- Press -Q- button to confirm input

Indicated on display


Channel 3 Adaptation 90 ->
Changed value is stored



- Press -> button to end adaptation.

Indicated on display


Rapid data transfer HELP
Insert address word XX



- Press buttons -1- and -0- to select "Adaptation" function 10 and press -Q- button to confirm input.


NOTE: If an incorrect entry is made, the VAG1551 will switch to the following display:


Indicated on display


Function is unknown ->
or cannot be carried out at the moment.



- Press -> button.
- Select "Adaptation" function 10 and adaptation channel 03 again.
- Repeat adaptation of fuel consumption display and press -Q- button to confirm input.